Gridcablemax hv cable sizing software made for engineers. Electrical design without appropriate software and tools is impossible to imagine. Gridcablemax is a user friendly program that determines cable ratings with total accuracy. For technical and economic reasons, the service voltage of medium voltage distribution networks rarely exceeds 36 kv. Motor voltage v ll, motor horsepower, cable temperature rating c, ambient temperature c, cable length ft and acceptable voltage drop %. Mv cable sizing calculation free download as pdf file. I am confused in three phase wire size calculation please let me know exact formula for three phase wire size calculation with multicore and single core cable. Pdf effective cable sizing model for building electrical services. Technical topic student minimising voltage differences short. Home download center electrical software cable size calculation spreadsheet. How to calculate size of a cable for 11kv or 33kv line. Fault level withstand is calculated and cable size increased if necessary. Calculate cable size and voltage drop electrical notes. Iec, nec, bs, etc and some standards emphasise certain things over others.
Power cable catalogue aai, a powerflo technologies company. There are three factors affecting the size of a cable. Lv and mv cables up to 33 kv with current capacity in accordance with bs 7671, era 6930 and iec 60502. Power factor for shortcircuits on lv sources calculation of lvsource phase impedances, based on ik3max calculation of lvsource neutral impedances, based on ik1min calculation of lvsource pe impedances, based on ief. It is better to use the table then the formula that you have provided. Cable sizing according to circuit breaker setting or rating. November 5, 2016 april 22, 2018 basicelectricaldesign calculation of nominal cross sectional area of the high voltage cable.
Along with the cable sizing calculation results, this section also displays the required cable sized, cable ampacity, percent of voltage drop, and percent of starting voltage if cable sizing options for the corresponding requirements are checked. Load current, short circuit current carrying capacity, voltage drop. Sep 12, 2017 cable sizing is done based on three parameters. We have a fully fledged application where you can size lv and mv cables up to 33 kv, current capacity in accordance with bs 7671, era 6930 and iec 60502 and with clear easy to read calculations and reports. I have looked at a few different bits of software for this but wondered if anyone could recommend anything else. Abb has always been a pioneer in the high voltage field and. See also cable sizing calculators for nec, iec 60364 and hd 60364 standards.
The basic philosophy underlying any cable sizing calculations are the same. Calculate the voltage drop of a defined cable and check the maximum length. If you continue without changing these settings, you consent to this. This excel sheet does the cable size calculation in three steps below. The general voltage levels covered by this publication are. Cable size calculation for 350 kw ht motor in case of lv system cable can be selected on the basis of its current carrying capacity and voltage drop but in case of mvhv system cable short circuit capacity is an importantdeciding factor. Typical calculations for a 20kv transformer feeder cable are presented. Oct 26, 20 this is the general methodology for sizing cables for any electrical systems. Pdf this paper mainly focuses on the sizing of electrical cables. High conductivity annealed stranded copper conductors to sans 1411 part 1. Pdf an effective cable sizing procedure model for industries and. Jan 18, 2019 download free excel program for cable sizing calculation.
By fn on 3 november, worked example of cable calculation electrical worked example of cable calculation see fig. However the general principles underlying any cable sizing calculation do not change. November 5, 2016 april 22, 2018 basicelectricaldesign. Below are given simple steps for performing cable sizing calculations. Advanced voltage drop calculator and voltage drop formula what is allowable voltage drop. Bs 7671, iee wiring regulations cable size is selected as follows. The term medium voltage is commonly used for distribution systems with voltages above 1 kv and generally applied up to and including 52 kv1. The type of cable insulation nominal and maximum operating voltage. This formula should be used to select the cable size necessary to meet a specific voltage drop limitation. The basic philosophy underlying any cable sizing calculation is to develop a procedure. Cable size calculations based on motor horse power hp and specified current.
I will be carrying out a lot of cable calculations ratings, pulling tensions etc. At present, numerous high voltage xlpe cable systems with nominal voltages up to 500 kv and. Formula to calculate voltage drop and energy losses. Medi ltage single conductor 5 35 mv cable copper mv cable aluminum nec table 310. Cable calculation software mvhv specific iet engineering. Voltage drop amperemeter which you will get from the cable supplier in mv.
All data used in this excel sheet are according to iee. Cable sizing, sustained current capacity bs 7671 wiring regulations, voltage drop clctr 50480, fault level and impedance iec 60909. Cablesizer cable sizing calculations to iec and nec standards. The cookies settings on this website are set to allow all cookies to give you the very best experience. Cable size calculation for 350 kw ht motor in case of lv system cable can be selected on the basis of its current carrying capacity and voltage drop but in case of mv hv system cable short circuit capacity is an importantdeciding factor. Dc ac drop voltage calculator photovoltaic software. Medium voltage underground cables 4 cable l cable power circuit design 7 n conductor 78 n conductor screen 8 n insulation 8 n insulation screen 89 n metallic screen 910 n outer protective sheath 1011 l table of cable elements 12 l cable constructions l cable drums 14 l cable tests following production 15 accessories l introduction 16 l connectors and lugs 16. Electrical load of 80kw, distance between source and load is 200 meter, system voltage 415v three phase, power factor is 0. In principle, factor tables can be used to initially size the cable and to provide close and approximate ampacities. Medium voltage technical guide electrical engineering portal. Power cable installation guide figure f5 multiple sheaves figure f6 sheave arrangements for feeding into cable tray training radius the training radius is the final positioning of cable ends after the cable has been placed in the raceway. In calculating the currentcarrying capacities, allowance has been made for dryingout of the soil. The required cable size is the largest size from shortcircuit, overload, and shock requirements. Rearrangement of this equation gives the maximum mva.
Cable sizing software electric cable sizing download the demo version of etaps as a cable sizing study module, etap cable sizing program calculates the cable size based on harmonic current flowing free download cable sizing excel winsite. Mv cable size calculation dear phil, you cable is more than enough if we asume the following, power factor 0. To ensure the optimal performance of our medium voltage cables as part of a system, we also supply a comprehensive range of mv cable accessories, including jointing kits, terminations, connectors and lugs. How to calculate voltage drop and size of electrical cable cable size calculation. No description max dist power load volt current csa mvam drop remain. However, the final cable ampacity may be different from the value obtained using coefficients from the factor tables. To find out more about how the cable sizing tool works, please see. No signups or logins required, just click below to start sizing to either nec or iec standards. Feb 08, 2014 calculate cable size and voltage drop. An effective cable sizing procedure model for industries and commerial buildings article pdf available in international journal of electrical and computer engineering 61.
Cable sizing software select, size and manage your power cables using mycableengineering. Notice as this catalogue is not intendedto cover all of liban cables sal possibilities in special cables manufacturing, the hereafter listing of the types of cables is not retrictive. Once you get all the above data, the voltage drop can be calculated as follows. For the wiring of industrial buildings, housing, control.
Calculation of nominal cross sectional area of the high voltage cable hv or ht cable. These limits should not be used for cables subjected to pulling tensions during installation. The inductive reactance per phase of a cable may be obtained by the formula. Insulated bundled overhead conductors torsade 1220 24 kv xlpe technical information formulae. Busway andor cable feeders distribution equipment and motor control power and lighting panelboards and motor control centers types of lighting systems installation methods power monitoring systems electric utility requirements trends in systems design there are many new factors to consider in. Voltage drop is calculated and cable size increased if necessary 3. Cablesizer cable sizing calculations to iec and nec. Download electrical cable size calculator excel sheet cable sizing is done based on three parameters. It considers current rating, voltage drop and short circuit current. The cable sizing calculator calculates the required cable size according to asnzs 3008 australia and new zealand standard. Power cable installation guide cables installed into conduits or trays have installation parameters such as maximum pulling tensions, sidewall pressure, clearance, and jamming, which must be considered. Mv protective device mv fuse technology type of mv relay. Description the sheet works with a series of input data giving you a number of calculated values.
Mv90 mv105 mv90 mv105 8 43 48 6 58 65 65 72 4 76 85 84 94 2 100 115 115 1 120 5 150 10 140 155 150 170 20 160 175 175 200 30 190 210 200 225 40 215 240 230 260 250 250 280 255 290 350 305 340 310 350 500 380 425 385 430 750 490 545 485 540 580 645 565 640 aacit ata medi ltage single conductor 5 35 mv cable copper. Cable size calculations calculations based on motor horse power hp and specified current. This is the demonstration page for our cable calculator application which can be downloaded and installed on your website. A medium voltage insulated cable circuit consists of three single core cables or one three core cable with terminations at each end to connect it to the transformer or switchgear in the network. This formula is used to calculate the voltage drop in a circuit when the cable size is known. Sizing conductors and selecting protection devices legrand. Assessment of the heat flow in the underground cable systems. Single and three core medium voltage cables according to international standard iec 60502 1. For example load current 45 a, voltage drop 3 %, cable lenght 10 meter, please tell me how to calculate 4core copper cable size for that. Cable installation method maximum, permissible crosssectional area cable sizing according to circuit breaker setting or rating number of additional touching circuits thirdorder harmonic distortion manual and alternate solutions additional derating coefficients for wiring systems waiver of overloadprotection requirements for safety circuits. Hi everyone, kindly give me guidance for the calculation of cable size. Calculate the load current from the load data available. Where a cable is totally surrounded by thermal insulation for a distance greater than 0.
Today, im talking about how to calculate voltage drop and size of. Our software has been designed to calculate the current rating, temperature rise and cable losses of high voltage power cables under multiple scenarios and installation conditions in accordance with iec standard 60287. The spreadsheet calculates cable size according to length, amperage, temperature and number group cables. The connection of an electrical installation to a mv utility distribution network. Cable size calculations electrical engineering portal. No download needed, direct access from your web browser.
How to calculate voltage drop and size of electrical cable. Cable sizing methods do differ across international standards e. Download also cable tray and conduit sizing excel sheet. Cablesizer is an automated cable sizing and design calculation tool to iec and nec standards. Cable calculation software mvhv specific hi, i am hoping someone might be able to offer some opinions. The development of high voltage xlpe cable systems goes back to the since then production and material technology have improved significantly, providing reliable and maintenancefree products to the utility industry. The formula, then, would determine the appropriate size of power cable to sustain both. Underground cable sizing is one of the most important concerns when designing. Practical power cable ampacity analysis ced engineering. On this page can be downloaded professional software for electrical design, mv and lv network and photometric calculations, voltage drop and short circuit calculations etc.
The main objective of this research work is to develop effective cable sizing model for building services. Here you will find out the key facts for cable sizing and cable calculation. For cable sizes in capacitor banks, we recommend using the table on page 42 of the panelbuilders guide. Electrical calculation tools are based upon schneider electric ecodial electrical network calculation wellknown software. Calculation of the cable ampacity considers only power cables since control cables. Effective cable sizing model for building electrical services. High voltage xlpe cable systems technical user guide. Calculate voltage drop and size of electrical cable for following data. Pdf cablesizer cable sizing to iec and nec standards. Pdf effective cable sizing model for building electrical. Cable sizing software cable sizing calculation etap. Quick online free voltage drop calculator and energy losses calculation, formula of electrical dc and ac power wire voltage drop for various cross section cables, power factor, lenght, line, threephase, single phase. Other installations, such as buried and aerial, have different installation parameters.